
Operating instructions FLYTEC 3010
Digital vario display / wind speed display
Altitude 1: Absolute altitude
Altitude 2: Relative altitude
Vane wheel sensor socket / rechargeable
key DOWN / zeroing altitude 2
Descent tone / descent alarm key
12. Changeover key Altitude 1 - Altitude 2
On1 or On2 (1). Two independent batteries (rechargeable). The switch should be set to OFF when the unit has switched off automatically.
Power voltage is indicated on the analog vario display (2) for approximately 10 seconds and «Po» for power on the digital vario
display. When all the segments in the ascent sector (green) light up, this indicates that the battery which has been switched on has an energy reserve
Inadequate power reserve is indicated continuously when switched on and during operation by the lighting up of one or several segments in the
descent sector (red) and «Po». If this occurs, the unit does not shift into operating mode.
Please refer to «CHANGEOVER TO RECHARGEABLE BATTERY OPERATION » for BATTERY charging information.
Power is automatically cut off approx. 15 mins after the unit is last used. The on/off switch must rst be set at OFF before
the unit can be used again.
1. Changeover into adjustment mode is effected by pressing a key (9, 10 or 12) for several (approx. 4) seconds. The corresponding
display will then ash intermittently and can be reset.
2. Use the reset key «Up» (7) or «Down» (8) to set the required value. When entering altitude gures, the number display can be speeded up by
3. Finish by pressing the corresponding original key. When setting the altitude there is automatic acknowledgement after approx. 10 sec.
Altitude 1: Absolute altitude. Can be set within weather-de pendent tolerances.
Relative altitude. Can be set whenever required over the whole measurement range and zeroed at any time by pressing the key «CLEAR
ALTI 2» (8). lt can also be cleared while ALTI 1 is shown on the display. Operating the changeover key ALTI 1-ALTI 2 (12) indicates the desired altitude
and marks it with an arrow. Pressing the changeover key (12) for several (approx, 4) seconds will cause the unit to change to the adjustment mode of
the altitude currently displayed (see Setting mode).
Altimeter 2 (ALTI 2) can be used to indicate a gain or loss in altitude, as it can be zeroed at any time using the key «CLEAR ALTI
2» (8), even while ALTI 1 is displayed.
Fully automatic segment display over the entire range. Individual segments remain displayed until the end of the rst scale sector is
reached. They are then deleted from zero in the second scale sector pass again until the end of the second scale sector is reached.
Display over the entire range.
Digital vario attenuntion:
Changeover into the vario attenuation settin mode is effected by pressing the volume key (10) for several (approx. 3
seconds (c.f. Setting mode). Four selectable average value computations are possible for the digital vario display:
d0 = average value for the last second (4 measurements per second)
d1 = average value for the last 3 seconds
d2 = average value for the last 10 seconds
d3 = average value for the last 30 seconds
The analog vario display is not attenuated.
Comentarios a estos manuales